It could be either a three-wire single-phase stator in which case it will have six laminated internal pole pieces and five mounting holes or (more likely) a three-phase stator with nine pole pieces and three mounting holes.
Which rectifier or regulator/rectifier does it have?
A single-phase (two-wire) RM21 would be the standard stator.
It could be either a three-wire single-phase stator in which case it will have six laminated internal pole pieces and five mounting holes or a three-phase stator with nine pole pieces and three mounting holes.
Which rectifier or regulator/rectifier does it have?
Three mounting holes and a Podtronics (with three yellow wires connected to the three stator wires?) should be either a 10.5A or 14.5A/16A three-phase RM24 stator.
Three mounting holes and a Podtronics (with three yellow wires connected to the three stator wires?) should be either a 10.5A or 14.5A/16A three-phase RM24 stator.
Three mounting holes and a Podtronics (with three yellow wires connected to the three stator wires?) should be either a 10.5A or 14.5A/16A three-phase RM24 stator.
It has to be a 3-phase (high or low output?) RM24 stator.
The three Podtronics to stator (AC) wires are normally yellow as previously mentioned (have they been extended with lengths of black wire?), with red positive and black negative.
It has to be a 3-phase (high or low output?) RM24 stator.
The three Podtronics to stator (AC) wires are normally yellow as previously mentioned (have they been extended with lengths of black wire?), with red positive and black negative.
Yes but the ends of the wires at the bottom frame rail are black. The connectors are such that the Gr/Y wire can only be connected to a specific lead from the regulator as is normal with the Podtronics. I'm aware of the fact that the A/C leads from the stator are not lead specific for the other 2 leads.. I do recall that the 3 wire stator on my '67 A65T had 2 that were combined for 12v applications, thus only 2 leads on the OEM rectifier.
For a 3 phase alternator feeding a 3 phase rect/regulator any of the 3 alternator wires can be connected to any of the 3 wires to the rect/regulator. Its only with an earlier single phase alternator with 3 wires that you need to worry about which way these 3 wires connect to the 2 wires of the single phase rect/regulator.
Old Britts oil pressure gage
CNW oil tank mod
Hagon shocks
Kegler swing arm pivot clamps
MK III head steady