LED turn signal indicator

Mofosheee

VIP MEMBER
Joined
Aug 2020
Messages
221
Country flag
I'm running LED turn signals with a solid state flasher on a 12V negative ground machine. Pictured is a standard 12V Lucas indicator bulb and socket. Does an LED option exist that will plug into the Lucas bulb socket? If not, what are my best options (parts to buy) for making an operational turn signal indication light? Thanks!
 

Attachments

  • LED turn signal indicator
    light bulb.jpeg
    321.6 KB · Views: 21
Yes there are standard format LED bulbs that fit the stock turn lamps. Note you will need to setup a "Tweaker" circuit to prevent the turn warning lamp from passing enough current to flash all 4 lamps at once. A simple diode connection is what is needed...but pre made up tweakers are available...see this page for diagram or ordering from UK: http://www.norbsa02.freeuk.com/GoffyLEDIndicators.htm

Another thing to consider...you should always use leds of same colour as the lens they will fit behind...so amber leds for amber turns, red for red brake/tail lamps. Otherwise you will loose a lot of brightness with a white led behind a coloured lens.
 
Yes there are standard format LED bulbs that fit the stock turn lamps. Note you will need to setup a "Tweaker" circuit to prevent the turn warning lamp from passing enough current to flash all 4 lamps at once. A simple diode connection is what is needed...but pre made up tweakers are available...see this page for diagram or ordering from UK: http://www.norbsa02.freeuk.com/GoffyLEDIndicators.htm

Another thing to consider...you should always use leds of same colour as the lens they will fit behind...so amber leds for amber turns, red for red brake/tail lamps. Otherwise you will loose a lot of brightness with a white led behind a coloured lens.
Pretty sure you will need to modify the flasher as well. Having half the load due to a burned out bulb changes the flash rate to be generally unacceptible.
 
Pretty sure you will need to modify the flasher as well. Having half the load due to a burned out bulb changes the flash rate to be generally unacceptible.
I think OP mentioned he had an LED compatible flasher. These are very common to get these days. Note there was also a old thread mentioning a Lucas 3-connection flashed where one wire was for direct control of the indicator warning light...no tweaker or resistor loads for LED lamps needed.
 