Hi

I recently bought a norton commando 1971 in parts. The electrical system seems to be modified, does not match the wiring diagram for this model. How can you find out if it is + or - earth? Most of the wiring is disconnected.

Wondering also if anyone is familiar with this:
Lucas O.P.U.S Ignition
Amplifier unit
AB5 type.
12V Neg. Earth

Is it the same as Rita AB5? Does the Rita also have negative earth?

/Johan
 
it depends on what parts you have for the charging circuit. if you still have the zener diode and rectifier than it is + earth if you have another regulator/rectifier most can can be wired either way and so can most electronic ignitions.
 
I have seen that there are both + and - grounded zener diodes. Is it enough to replace zener diode and rectifier to build a negative ground system?
 
if you have to buy new parts or want to chang it to - earth than you would be better off with one of the reg/rectifier units. like I stated if it has the zener it is + earth as I don't think some one would change it to - earth using a zener
 
jl04279 said:
I have seen that there are both + and - grounded zener diodes. Is it enough to replace zener diode and rectifier to build a negative ground system?

From what I've seen Lucas did make some negative ground rectifiers and zener diodes late in the game but as was said if you wanted to do a conversion a $50 Podtronics (or similar) unit would be simpler and less expensive
 